    Vitamin C in Plasma/Serum - Automated HPLC

    Order no.: 65765/F
    480 Tests
    • Vitamin C

    Automated sample preparation with 96 well filter plates

    DESCRIPTION

    Clinical relevance

    Vitamin C (ascorbic acid, ascorbate) is a water-soluble vitamin that is an essential cofactor for the human body, for instance in the catabolism of tyrosine and the synthesis of catecholamines. Regular consumption of fruit and vegetables is usually sufficient to cover the body’s vitamin C needs.

    In the case of vitamin C deficiency, procollagen chains are produced insufficiently and stable fibrils cannot be formed in the affected cells. Without functioning collagen, the blood vessels and tendons become fragile and the typical skin-related symptoms associated with scurvy start to develop. In addition to the collagen damages described above, further diseases caused by vitamin C deficiency include bleeding of uncertain origin, loss of teeth and overactive thyroid gland (hyperthyroidism). Vitamin C deficiency is also observed in dialysis patients, in chronic alcohol abuse and during pregnancy.

     

    Product advantages

    • High stability of processed samples and controls
    • Enhanced column stability
    • Reliable quantification with a stable internal standard

     

    This Chromsystems kit allows the reliable chromatographic determination of vitamin C in one isocratic HPLC run with UV detection. An efficient protein precipitation step removes interfering components and stabilises Vitamin C simultaneously. A stable internal standard is used for reliable quantification. Due to a special stabilisation of the prepared samples, it is also possible to reliably process and measure large sample batches.

     

    Kit content

    Mobile Phase, 1000 ml
    Vitamin C Plasma Calibration Standard (lyoph.), 5 x 0.5 ml
    Internal Standard, 10 ml
    96 Well filter plates, 5 pcs.
    Collection plates, 5 pcs.
    Pierceable adhesive seals for 96 well plates, 5 pcs.
     

     

    CHROMATOGRAM

    65765 F HPLC kit vitamin C - Chromatogram EN

    TECHNICAL DATA

    Method of Analysis

    HPLC

    Number of Tests

    480

    Parameter

    Vitamin C

    Analysis Time

    5 min

    Limit of quantification

    0.5 mg/l

    Linearity

    up to 120 mg/l

    Intraassay

    CV <= 3 %

    Interassay

    CV < 6 %

    Information

    Any isocratic HPLC system with UV detection is suitable.

    Specimen

    Plasma/Serum

    Pre-analytic Treatment

    Specimens: Fresh lithium heparin plasma

    Sample stability: 5 days at -20 °C, up to 2 hours at room temperature
    Detailed information on stability and transportation can be obtained from the instruction manual.

    Sample Preparation

    • Place 100 µl Internal Standard in a 96 well filter plate.
    • Add 100 µl sample/calibrator/control.
    • Vortex for 30 s at 1100 rpm (orbit: 2 mm).
    • Centrifuge for 5 min at 2000 x g.
    • Close the 96 well filter plate.
    • Vortex for 30 s at 800 rpm (orbit: 2 mm).
    • Inject 20 µl of the prepared sample into the HPLC system.

    Additional Info

    For the Chromsystems HPLC analysis of vitamin C any isocratic HPLC system with UV detection is suitable.

    Injection Volume

    20 µl

    Flow rate

    1.5 ml/min

    Flow

    1.5 ml/min

    Gradient

    Isocratic

    Column temperature

    ambient (~25 °C)

    Wavelength

    245 nm

    Please note

    The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals.

    KIT COMPONENTS

    Components available separately

    Mobile Phase


    Order no.: 65001

    DETAILS

    Mobile Phase, 10 x 1000ml


    Order no.: 65002

    DETAILS

    Vitamin C Plasma Calibration Standard


    Order no.: 65003

    DETAILS

    Internal Standard


    Order no.: 65044

    DETAILS

    96 Well Filter Plates


    Order no.: 65757

    DETAILS

    Collection Plates


    Order no.: 65758

    DETAILS

    Pierceable adhesive seals for 96 Well Plates


    Order no.: 65759

    DETAILS

    ACCESSORIES

    PEEK prefilter housing


    Order no.: 15010

    DETAILS

    HPLC column


    Order no.: 65100

    DETAILS

    PEEK-encased prefilter, 5 µm


    Order no.: 15009

    DETAILS

    Precolumn cartridge 4/10


    Order no.: 18065

    DETAILS

    Precolumn cartridge holder 4/10


    Order no.: 18001

    DETAILS

    CALIBRATORS

    Calibrators available separately

    Vitamin C Plasma Calibration Standard


    Order no.: 65003

    DETAILS

    CONTROLS

    Controls available separately

    Vitamin C Plasma Controls


     

    DETAILS

溫馨提示:不可用于臨床治療。
上一篇:72058Waste Plates
 相關同類產品:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數(shù)字),如:三加四=7

版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:103268  sitemap.xml

欧美一区二区三区久久久久久桃花| 五月婷婷之综合激情| 大荫蒂视频欧美另类xx| 国产精品福利电影| 国产精品久久久久久久女厕留拍| а√天堂资源官网在线资源| 欧美激情h| 一本久道久久综合狠狠爱| 丰满人妻猛烈进入中文字幕 | 一本色道a毛毛人妻精品69| 波岛野结衣| 国产精品扒开腿做爽爽的免费软件| 国产精品亚洲a| 99亚洲国产精品| 日韩精品不卡视频| 国产精品久线在线观看| 91在线一区二区三区| 99热在线免费播放| 人妻少妇精品视频一区二区三区蜜臀 | 日本新JAPANESE乱熟| 漂亮韩国理伦片在线观看| 亚洲va欧美va国产va| 亚洲成人黄色在线| 国产揄拍国产精品人妻蜜| 中文字幕色偷偷人妻久久一区| 最近免费中文字幕| 69xxx欧美| 激情久久一区二区| 亚洲精品中文字幕在线| 午夜视频在线| 欧美熟妇www| 欧美人与动性xxxxx杂性| 狂吃奶头狂叫60分钟视频| 成年人免费在线观看视频网站| 国产主播av| 久久久久成人精品免费播放| 最新视频免费观看入口| 在线精品亚洲一区二区佐佐木明希| 国产成人午夜高潮毛片刘涛| 国产一区二区三区最好精华液| 少妇一晚三次一区二区三区|